Pulsation Dampener Metric

Step #1: Calculate the Volume per Stroke.


Volume / Stroke (mL) = (LPH / Strokes/Min) x 1000


Step #2: Fill in the remaining values and calculate.


Dampener Size (C) = (V) x (K) x (SP/ Pmin)y
1 – (SP/ Pmax)y
Where V = Volume / Stroke (mL)
SP = Mean System Pressure (Pmin + Pmax) /2
Pmin = Minimum Discharge Pressure in bar
Pmax = Maximum Discharge Pressure in bar
K = Constant from the Pump-type Table shown in menu
Y = 1 (if charged with Compressed Air); 0.714 (if charged with Nitrogen)
(mL)
(type of pump)
(bar)
%